学科分类
/ 2
25 个结果
  • 简介:本文介绍中国第一条从北京房山变电站至昌平变电站全长83公里的500kV紧凑型输电线路在投运前、后所做的多次试验的情况。试验结果表明所有电气参数完全符合设计要求。

  • 标签: 紧凑型输电线路 过电压 操作过电压 参数
  • 简介:

  • 标签:
  • 简介:±500KVHVDCTransmissionprojectfromTianshengqiaotoGuangzhouLiLicheng,PengBaoshu,YuJianguo,WuZehuiPowerNetwork,ConstructionDepar...

  • 标签: HVDC
  • 简介:AccordingtothepowersystemplanninginChina,500kVtransmissionlinewillbethetrunksinallregionalnetworksexcepttheNorthwestChinaSystem.Duetoshortofcapitalresources,however,mostofthose500kVtransmissionlinesareandwillbeoperatinginsinglecircuitforquitealongpe-riodoftime.So,tousetheliveworkingtechniqueson500kVlinesisanimportantproblemforstudy.Actually,wehadalreadybegunourstudyonliveworkingon500kVtransmissionlineseveralyearspriortothePing-Wu

  • 标签: prior STRING suspension INSULATOR NORTHWEST WORKER
  • 简介:Thestrengthofthepowerfrequencyelectricintensityandmagneticfieldofthe500-kVdoublecircuittransmissionlineswascalculatedbyusingtheequivalentchargemethodandtheAmpere'sLaw,andtheenvironmentalimpactfactorsofthefieldswereevaluated.Byoptimizingthephasesequence,thefrequencyelectricintensityandmagneticfieldstrengthcanbereduced.Withinadistanceof25mfromthecenterofthetransmissionline,thepowerfrequencyelectricintensityandmagneticfieldstrengthfalloffsharplywiththedistanceincrease.Finally,thebestphasesequenceandtheminimumgroundclearanceofthetransmissionlineswereobtainedtomeettherequirementsoftheleastimpactonenvionment.

  • 标签: 双回输电线路 电磁环境 磁场强度 环境影响因素 电场强度 等效电荷
  • 简介:ItisacommonpracticeinChinatouseaninsulatedsilkjacklad-derinthelive-lineworktoenterthe500kVEHVelectricfield.WuhanHighVoltageResearchInstitutehassuccessfullycarriedoutsuchoperatingperformanceatthemeetingofESMO-90inCanada.(Fig.1)Theoperatingprocedureisnowrecommendedasfollows.

  • 标签: LADDER Wuhan Canada insulated recommended nylon
  • 简介:DuringtwoyearsoddperiodfromDec.1987toFeb.1990,therehadbeenrepeatedlypollution-flashoverfailuresonour500kVtransmissionlines,resultinginawidescopeblackout.Therewereeleven500kVlinesaltogetherinNorth-east,EastandNorthChinapowergrids,wherepollution-flashoverfailureshappenedoneafteranotheron36transmissionlinetowers(poles).Since500kVtransmissionlinesarethemaintrunksofhighvoltage

  • 标签: strings repeatedly eleven PREVENTIVE adjustment GASES
  • 简介:OnOctober12thisyear,thecontractsoftheprocurementontheconverterstationequipmentforThreeGorges-GuangdongandGuizhou-Guangdong±500kVDCtransmissionprojects,know-howtransferandthesubcontractsonequipmentmanufacturinghasbeensigned.Theconstructionscaleofthetwoprojectsis

  • 标签:
  • 简介:Beingabundantinhydropower,coal,windenergyandsolarenergyetc.,NorthwestChinaisanimportantenergybasewithgreatpotential.Inrecentyears,alongwiththevigorousdevelopmentoftheenergybase,the

  • 标签:
  • 简介:Theretrofitprojectof800-kVlargecapacityexperimentsysteminXi'anHighVoltageEquipmentResearchInstitutewascompletedsometimeago.Thesystemcanmeetrequirementsofwholepoleexperimentof550-kV63-kAand800-kV63-kAcircuitbreakersbyIECNorm.Itscapacitortowerisover100tinweightand15minheight.Thevoltageofeachcapacitorbankcanreach1000kV.

  • 标签: 西安 高压设备 容量 发展策略
  • 简介:OnJanuary10,2011,the750-kVTurpan-Bayinguolengtransmission-substationprojectofXinjiangpowergrid,officiallywentintooperation.Henceforth,thehardtimeofstaggeringpowerutilizationandlimitingpowerutilizationinpeakperiodinBazhou,Aksu,Kashi,KezhouandHotanfiveprefecturesinsouthXingjiangwillneverreturn.

  • 标签: 变电工程 投产 电能利用率 输电 吐鲁番 变电站
  • 简介:Helicopterinspectionofultrahighvoltage(UHV)transmissionlineshasunmatchedadvantagescomparedtomanualworkduetotheinspectionangleandhigh-techequipmentonboard,especiallyindetailedinspectionsoftowerheadsanddefect-detectionsinvirtueofinfrared/ultraviolettechniques.Thispaperdealswithsomekeytechnicalproblemsintheinspectionsof1000kVUHVAClineswithahelicopter,suchasthesafedistanceoflive-lineworking,electromagneticfieldintensityandflightcontrol.Basedonthestudyresults,asetofUHVlineinspectionmethodswasworkedoutandappliedtotheinspectionofliveUHVlines.

  • 标签: 安全距离 直升机 特高压 紫外线技术 流线 高压线路
  • 简介:局部放电是额定6kV或变高电压的电动机与发电机中发现的大多数定子绕组绝缘劣化机理的表征,因而,对局部放电的测试作为确定这类高压电机定子是否需要维修的一种方法已应用了40多年,由于这种测试的好处越来越为人们所认识,也就有了将局部放电测试应用于4kV电动机与发电机绕组的兴趣,本文论述了可能限制4kV定子测试的理论上的原因,陈述了一系列表明局部放电确实发生的脱线局部放电试验的结果,过去两年中对大约10台4kV电动机上进行的一系列在线局部放电试验的结果表明局部放电只可能发生在由于一些类型的故障机理引起的故障发生之前很短一段时间,因此,为了防止在使用中出现故障,有必要进行连续监测,本文对一种便宜的连续局部放电监控器进行了描述,局部放电监测似乎在只用于非常关键生产过程的电动机及发电机上,才是有成本效益的,因为运行中的可能引起巨大的经济损失。

  • 标签: 电绝缘 维修 局部放电 旋转电机 定子绕组